Golem shot: 4863

2011-03-22 - 123456

Basic parameters:
  • Chamber pressure pchamber : 2.47->10.56 mPa (request: 10 mPa)
  • Chamber temperature: 120 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 16340 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.5 over 5.48 to 13.98 [ms]
  • Mean toroidal magnetic field Bt: 0.213 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: 10.1 V
  • Break down voltage: 11.6 V
  • Plasma total charge: 6.2 C
  • Ohmic heating power: 11.1 kW
  • Q edge: 17.5
  • Central electron temperature: 20.5 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and