Tokamak GOLEM - Shot Database - #48780

| Time stamp | |
|---|
| 25-04-30 11:05:42 |
[Shot logbook]| The session mission | Experiments/PlasmaRegimes/MinimumStabilizationFull steam |
|---|
The session ID  | 48775  |
|---|
| The discharge comment | Test CST #48726 with more start negative value of voltage (-10Volt) on FG with very similar vaweform |
|---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=900,t_Bt=0,U_cd=350,t_cd=600,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mod ... |
Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Fast cameras Data flow:

Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
Off stage diagnostics
Mirnov coils @ Limiter Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=350,t_cd=600,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=10,U_v=22
Position stabilization
:
Parameters

:main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,-2;9000,-10;16000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-2;10000,-10;13000,-20;16000,-10;30000,0'
Current stabilization POKUS2
Parameters
:main_switch='on',waveform='1000,0;2000,0;15000,-10;16000,-8;17000,-6;18000,-4;19000,-2;20000,-1;21000,2;22000,4;23000,6;24000,8;25000,10;26000,12;27000,14;28000,16;29000,18;30000,14;31000,10;32000,6;33000,4;34000,2;35000,-4;36000,-8;37000,-12;38000,-16;39000,-18;40000,0;41000,0;42000,0;43000,0;44000,0;45000,0;46000,0;47000,0;48000,0;49000,0;50000,0'
 |
 |
 |
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 