Golem shot: 4892

2011-03-23 - 095230

Basic parameters:
  • Chamber pressure pchamber : 2.43->20.51 mPa (request: 20 mPa)
  • Chamber temperature: 156 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 13099 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.99 over 7.72 to 16.71 [ms]
  • Mean toroidal magnetic field Bt: 0.298 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 11.5 V
  • Break down voltage: 13.6 V
  • Plasma total charge: 16.5 C
  • Ohmic heating power: 24.2 kW
  • Q edge: 12.8
  • Central electron temperature: 28.9 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and