Golem shot: 4897

2011-03-23 - 100921

Basic parameters:
  • Chamber pressure pchamber : 2.32->20.12 mPa (request: 20 mPa)
  • Chamber temperature: 110 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14104 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.3 over 7.59 to 15.89 [ms]
  • Mean toroidal magnetic field Bt: 0.278 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: 9.0 V
  • Break down voltage: 11.6 V
  • Plasma total charge: 17.5 C
  • Ohmic heating power: 20.7 kW
  • Q edge: 10.9
  • Central electron temperature: 36.2 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and