Golem shot: 4901

2011-03-23 - 102203

Basic parameters:
  • Chamber pressure pchamber : 2.45->20.04 mPa (request: 20 mPa)
  • Chamber temperature: 580 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14870 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.53 over 8.01 to 16.54 [ms]
  • Mean toroidal magnetic field Bt: 0.283 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: 9.2 V
  • Break down voltage: 11.8 V
  • Plasma total charge: 18.8 C
  • Ohmic heating power: 21.2 kW
  • Q edge: 11.1
  • Central electron temperature: 35.6 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and