Golem shot: 4908

2011-03-23 - 111123

Basic parameters:
  • Chamber pressure pchamber : 2.29->20.66 mPa (request: 20 mPa)
  • Chamber temperature: 579 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 17826 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.93 over 8.8 to 16.73 [ms]
  • Mean toroidal magnetic field Bt: 0.276 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: 9.0 V
  • Break down voltage: 11.1 V
  • Plasma total charge: 20.6 C
  • Ohmic heating power: 20.7 kW
  • Q edge: 10.8
  • Central electron temperature: 36.2 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and