Golem shot: 4949

2011-03-24 - 130733

Basic parameters:
  • Chamber pressure pchamber : 2.86->20.90 mPa (request: 20 mPa)
  • Chamber temperature: 18 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4225 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.71 over 7.32 to 15.03 [ms]
  • Mean toroidal magnetic field Bt: 0.262 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: 11.0 V
  • Break down voltage: 13.0 V
  • Plasma total charge: 16.5 C
  • Ohmic heating power: 25.3 kW
  • Q edge: 10.3
  • Central electron temperature: 31.6 eV

DASs:

TektronixDPO3014
New diagnostics: (configuration)

Lring_PV
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and