Golem shot: 4952

2011-03-24 - 134744

Basic parameters:
  • Chamber pressure pchamber : 2.88->20.19 mPa (request: 20 mPa)
  • Chamber temperature: 20 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6631 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.77 over 7.23 to 15 [ms]
  • Mean toroidal magnetic field Bt: 0.259 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: 10.9 V
  • Break down voltage: 13.1 V
  • Plasma total charge: 16.6 C
  • Ohmic heating power: 25.1 kW
  • Q edge: 10.2
  • Central electron temperature: 31.8 eV

DASs:

TektronixDPO3014
New diagnostics: (configuration)

Lring_PV
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and