2011-03-24 - 193840

Basic parameters:
  • Chamber pressure pchamber : 2.75->20.66 mPa (request: 20 mPa)
  • Chamber temperature: 20 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5127 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 5.72 over 25.23 to 30.95 [ms]
  • Mean toroidal magnetic field Bt: 0.089 T
  • Mean plasma current: 14.6 kA
  • Mean Uloop: 5.4 V
  • Break down voltage: 2.5 V
  • Plasma total charge: 368.0 C
  • Ohmic heating power: 78.8 kW
  • Q edge: 0.6
  • Central electron temperature: 174.3 eV

DASs:

NI

TektronixDPO3014
New diagnostics: (configuration)

Lring_PV

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and