Golem shot: 4989

2011-03-24 - 210527

Basic parameters:
  • Chamber pressure pchamber : 2.24->20.90 mPa (request: 20 mPa)
  • Chamber temperature: 20 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 650 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10334 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.76 over 4.08 to 12.84 [ms]
  • Mean toroidal magnetic field Bt: 0.240 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 11.5 V
  • Break down voltage: 15.3 V
  • Plasma total charge: 8.2 C
  • Ohmic heating power: 23.0 kW
  • Q edge: 10.8
  • Central electron temperature: 28.0 eV

DASs:

NI

TektronixDPO3014
New diagnostics: (configuration)

Lring_PV

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and