Golem shot: 4996

2011-03-24 - 221140

Basic parameters:
  • Chamber pressure pchamber : 2.75->19.58 mPa (request: 20 mPa)
  • Chamber temperature: 21 grad C
  • CBt capacitors (23 mF) charged to: 1350 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 650 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14299 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.64 over 5.02 to 12.66 [ms]
  • Mean toroidal magnetic field Bt: 0.208 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: 12.3 V
  • Break down voltage: 13.4 V
  • Plasma total charge: 8.0 C
  • Ohmic heating power: 19.7 kW
  • Q edge: 11.7
  • Central electron temperature: 23.1 eV

DASs:

NI

TektronixDPO3014
New diagnostics: (configuration)

MirnovCoils_TM

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and