Golem shot: 5013

2011-03-29 - 125422

Basic parameters:
  • Chamber pressure pchamber : 15.08->15.03 mPa (vacuum shot)
  • Chamber temperature: 20 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11277 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.17 over 9.03 to 17.2 [ms]
  • Mean toroidal magnetic field Bt: 0.114 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: 6.7 V
  • Break down voltage: 9.0 V
  • Plasma total charge: 17.6 C
  • Ohmic heating power: 12.7 kW
  • Q edge: 5.4
  • Central electron temperature: 38.8 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and