Golem shot: 5018

2011-03-29 - 131031

Basic parameters:
  • Chamber pressure pchamber : 15.55->13.19 mPa (vacuum shot)
  • Chamber temperature: 28 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 12245 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.21 over 4.8 to 13.01 [ms]
  • Mean toroidal magnetic field Bt: 0.101 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: 6.2 V
  • Break down voltage: 9.5 V
  • Plasma total charge: 7.8 C
  • Ohmic heating power: 9.9 kW
  • Q edge: 5.7
  • Central electron temperature: 36.4 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and