Basic parameters:
  • Chamber pressure pchamber : 12.89->10.88 mPa (vacuum shot)
  • Chamber temperature: 29 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 19097 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.17 over 2.41 to 10.58 [ms]
  • Mean toroidal magnetic field Bt: 0.084 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 6.5 V
  • Break down voltage: 9.3 V
  • Plasma total charge: 2.4 C
  • Ohmic heating power: 6.5 kW
  • Q edge: 7.6
  • Central electron temperature: 25.8 eV