Tokamak GOLEM - Shot Database - #50318

| Time stamp | |
|---|
| 25-11-03 16:50:59 |
[Shot logbook]| The session mission | BasicOperationBasic operation withou probes on manipulators |
|---|
The session ID  | 50318  |
|---|
| The discharge comment | Master test inspired by #50170 s úvodním BD stouchem |
|---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=900,t_Bt=0,U_cd=300,t_cd=200,O_Bt='CW',O_cd='CW'" --infrastru ... |
Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Off stage diagnostics
Interferometry Data flow:

Documentation:
Fast cameras Data flow:
Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
Slow optical spectrometry Data flow:
Documentation:
Scintillation probes Data flow:
Documentation:

Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Mirnov coils @ Limiter Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=300,t_cd=200,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=15,U_v=22
Preionization
Parameters
:S_device='HotCathode',SW_main='off',U_heater=90,U_accel=100
Position stabilization
:
Parameters
:main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,0;6500,-1;6800,-2;8000,-7;9000,-15;12000,-20,30000,-20;35000,0',vertical_switch='on',vertical_waveform='1000,0;9000,0;9500,-1;9800,-2;10000,-5;11000,-10;15000,-15;30000,-13;35000,0'
Current stabilization
Parameters
:main_switch='on',waveform='1000,0;500,0;5000,-20;9000,-20;15000,0;17000,6;19000,10;21000,15;30000,15;50000,0'
 |
 |
 |
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 