Golem shot: 5037

2011-03-30 - 145747

Basic parameters:
  • Chamber pressure pchamber : 9.70->9.66 mPa (vacuum shot)
  • Chamber temperature: 19 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5747 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.17 over 7.64 to 15.81 [ms]
  • Mean toroidal magnetic field Bt: 0.113 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: 7.4 V
  • Break down voltage: 9.0 V
  • Plasma total charge: 11.8 C
  • Ohmic heating power: 11.1 kW
  • Q edge: 6.8
  • Central electron temperature: 31.0 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and