Golem shot: 5038

2011-03-31 - 140911

Basic parameters:
  • Chamber pressure pchamber : 8.10->8.10 mPa (vacuum shot)
  • Chamber temperature: 24 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2969 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.16 over 9.21 to 17.37 [ms]
  • Mean toroidal magnetic field Bt: 0.116 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 6.7 V
  • Break down voltage: 9.0 V
  • Plasma total charge: 18.4 C
  • Ohmic heating power: 13.4 kW
  • Q edge: 5.2
  • Central electron temperature: 40.1 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and