Golem shot: 5048

2011-03-31 - 145903

Basic parameters:
  • Chamber pressure pchamber : 8.22->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 24 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5959 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.96 over 8.03 to 15.99 [ms]
  • Mean toroidal magnetic field Bt: 0.107 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 8.9 V
  • Break down voltage: 11.1 V
  • Plasma total charge: 16.5 C
  • Ohmic heating power: 18.7 kW
  • Q edge: 4.6
  • Central electron temperature: 34.3 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and