Golem shot: 5060

2011-03-31 - 185654

Basic parameters:
  • Chamber pressure pchamber : 8.19->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 20241 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.4 over 9.82 to 18.22 [ms]
  • Mean toroidal magnetic field Bt: 0.135 T
  • Mean plasma current: 3.2 kA
  • Mean Uloop: 9.5 V
  • Break down voltage: 13.2 V
  • Plasma total charge: 31.2 C
  • Ohmic heating power: 30.4 kW
  • Q edge: 3.8
  • Central electron temperature: 43.5 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and