Golem shot: 5062

2011-03-31 - 200748

Basic parameters:
  • Chamber pressure pchamber : 8.29->32.38 mPa (request: 35 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 24495 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.33 over 2.06 to 10.39 [ms]
  • Mean toroidal magnetic field Bt: 0.099 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 10.5 V
  • Break down voltage: 14.5 V
  • Plasma total charge: 2.1 C
  • Ohmic heating power: 10.5 kW
  • Q edge: 8.9
  • Central electron temperature: 18.7 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and