Golem shot: 5067

2011-03-31 - 202019

Basic parameters:
  • Chamber pressure pchamber : 8.48->20.12 mPa (request: 20 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 25261 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.95 over 9.13 to 17.08 [ms]
  • Mean toroidal magnetic field Bt: 0.197 T
  • Mean plasma current: 2.4 kA
  • Mean Uloop: 10.9 V
  • Break down voltage: 9.9 V
  • Plasma total charge: 21.5 C
  • Ohmic heating power: 26.2 kW
  • Q edge: 7.4
  • Central electron temperature: 32.7 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and