Golem shot: 5071

2011-03-31 - 202735

Basic parameters:
  • Chamber pressure pchamber : 8.58->27.14 mPa (request: 30 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 50 V, triggered 6,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 25692 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.3 over 8.14 to 17.44 [ms]
  • Mean toroidal magnetic field Bt: 0.219 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 7.9 V
  • Break down voltage: 12.7 V
  • Plasma total charge: 11.6 C
  • Ohmic heating power: 11.1 kW
  • Q edge: 14.1
  • Central electron temperature: 28.3 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and