Golem shot: 5072

2011-03-31 - 202928

Basic parameters:
  • Chamber pressure pchamber : 8.65->35.23 mPa (request: 35 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 100 V, triggered 6,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 25809 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.39 over 9.12 to 17.51 [ms]
  • Mean toroidal magnetic field Bt: 0.205 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: 9.5 V
  • Break down voltage: 14.9 V
  • Plasma total charge: 14.0 C
  • Ohmic heating power: 14.2 kW
  • Q edge: 12.3
  • Central electron temperature: 26.2 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and