Golem shot: 5077

2011-03-31 - 203837

Basic parameters:
  • Chamber pressure pchamber : 8.61->50.93 mPa (request: 50 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 26357 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.15 over 7.43 to 17.58 [ms]
  • Mean toroidal magnetic field Bt: 0.223 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: 12.1 V
  • Break down voltage: 14.9 V
  • Plasma total charge: 11.9 C
  • Ohmic heating power: 19.4 kW
  • Q edge: 12.6
  • Central electron temperature: 23.3 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and