Golem shot: 5078

2011-03-31 - 204032

Basic parameters:
  • Chamber pressure pchamber : 8.61->24.18 mPa (request: 20 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 200 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 26468 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.19 over 1.62 to 8.81 [ms]
  • Mean toroidal magnetic field Bt: 0.111 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 10.2 V
  • Break down voltage: 10.6 V
  • Plasma total charge: 1.7 C
  • Ohmic heating power: 10.2 kW
  • Q edge: 10.0
  • Central electron temperature: 19.1 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and