Golem shot: 5079

2011-03-31 - 204224

Basic parameters:
  • Chamber pressure pchamber : 8.75->23.10 mPa (request: 25 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 26585 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.25 over 8.29 to 16.54 [ms]
  • Mean toroidal magnetic field Bt: 0.202 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: 9.5 V
  • Break down voltage: 9.2 V
  • Plasma total charge: 14.8 C
  • Ohmic heating power: 17.1 kW
  • Q edge: 10.1
  • Central electron temperature: 29.6 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and