Golem shot: 5081

2011-03-31 - 204542

Basic parameters:
  • Chamber pressure pchamber : 8.71->31.88 mPa (request: 30 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 300 V, triggered 6,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 26781 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.1 over 8.6 to 16.7 [ms]
  • Mean toroidal magnetic field Bt: 0.196 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 12.1 V
  • Break down voltage: 12.8 V
  • Plasma total charge: 17.8 C
  • Ohmic heating power: 25.4 kW
  • Q edge: 8.4
  • Central electron temperature: 27.9 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and