Golem shot: 5083

2011-03-31 - 204935

Basic parameters:
  • Chamber pressure pchamber : 8.68->19.36 mPa (request: 20 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 125 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 27016 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.07 over 8.95 to 17.02 [ms]
  • Mean toroidal magnetic field Bt: 0.193 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: 9.7 V
  • Break down voltage: 8.8 V
  • Plasma total charge: 16.1 C
  • Ohmic heating power: 17.5 kW
  • Q edge: 9.7
  • Central electron temperature: 29.2 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK