Golem shot: 5085

2011-03-31 - 205315

Basic parameters:
  • Chamber pressure pchamber : 8.61->20.04 mPa (request: 20 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 125 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 27227 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.99 over 8.8 to 16.79 [ms]
  • Mean toroidal magnetic field Bt: 0.163 T
  • Mean plasma current: 2.2 kA
  • Mean Uloop: 11.1 V
  • Break down voltage: 10.2 V
  • Plasma total charge: 19.8 C
  • Ohmic heating power: 24.4 kW
  • Q edge: 6.7
  • Central electron temperature: 30.5 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and