Golem shot: 5088

2011-03-31 - 205851

Basic parameters:
  • Chamber pressure pchamber : 8.68->8.58 mPa (vacuum shot)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 175 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 100 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 27562 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 5.87 over 2.5 to 8.37 [ms]
  • Mean toroidal magnetic field Bt: 0.083 T
  • Mean plasma current: -0.9 kA
  • Mean Uloop: 8.3 V
  • Break down voltage: 0.0 V
  • Plasma total charge: -2.2 C
  • Ohmic heating power: 7.5 kW
  • Q edge: 8.3
  • Central electron temperature: 20.4 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and