Golem shot: 5091

2011-03-31 - 210433

Basic parameters:
  • Chamber pressure pchamber : 8.48->50.93 mPa (request: 50 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 6,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 300 V, triggered 3,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 27917 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.85 over 1.83 to 10.68 [ms]
  • Mean toroidal magnetic field Bt: 0.174 T
  • Mean plasma current: -1.2 kA
  • Mean Uloop: 11.4 V
  • Break down voltage: 0.2 V
  • Plasma total charge: -2.2 C
  • Ohmic heating power: 13.7 kW
  • Q edge: 13.1
  • Central electron temperature: 20.0 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and