Golem shot: 5093

2011-03-31 - 210828

Basic parameters:
  • Chamber pressure pchamber : 8.71->8.55 mPa (vacuum shot)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 300 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 28151 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.9 over 7.87 to 16.77 [ms]
  • Mean toroidal magnetic field Bt: 0.204 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: 11.8 V
  • Break down voltage: 9.1 V
  • Plasma total charge: 14.6 C
  • Ohmic heating power: 22.4 kW
  • Q edge: 9.7
  • Central electron temperature: 26.6 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and