Golem shot: 5094

2011-03-31 - 211026

Basic parameters:
  • Chamber pressure pchamber : 8.51->21.80 mPa (request: 20 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 125 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 28267 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.07 over 8.1 to 17.17 [ms]
  • Mean toroidal magnetic field Bt: 0.214 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 11.5 V
  • Break down voltage: 10.3 V
  • Plasma total charge: 16.6 C
  • Ohmic heating power: 23.0 kW
  • Q edge: 9.7
  • Central electron temperature: 28.0 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and