Golem shot: 5096

2011-03-31 - 211410

Basic parameters:
  • Chamber pressure pchamber : 8.65->50.73 mPa (request: 50 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 6,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 300 V, triggered 6,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 28492 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 11.19 over 7.3 to 18.49 [ms]
  • Mean toroidal magnetic field Bt: 0.237 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: 12.2 V
  • Break down voltage: 15.7 V
  • Plasma total charge: 10.7 C
  • Ohmic heating power: 18.3 kW
  • Q edge: 14.3
  • Central electron temperature: 22.2 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and