Golem shot: 5109

2011-04-04 - 142037

Basic parameters:
  • Chamber pressure pchamber : 6.87->6.87 mPa (vacuum shot)
  • Chamber temperature: 59 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8201 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.09 over 2.15 to 10.24 [ms]
  • Mean toroidal magnetic field Bt: 0.078 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 8.5 V
  • Break down voltage: 11.4 V
  • Plasma total charge: 2.2 C
  • Ohmic heating power: 8.5 kW
  • Q edge: 7.0
  • Central electron temperature: 21.6 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and