Golem shot: 5128

2011-04-04 - 153301

Basic parameters:
  • Chamber pressure pchamber : 7.03->7.03 mPa (vacuum shot)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 410 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.36 over 8.31 to 16.67 [ms]
  • Mean toroidal magnetic field Bt: 0.094 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: 6.8 V
  • Break down voltage: 9.2 V
  • Plasma total charge: 14.7 C
  • Ohmic heating power: 12.2 kW
  • Q edge: 4.7
  • Central electron temperature: 37.0 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and