Golem shot: 5147

2011-04-04 - 164025

Basic parameters:
  • Chamber pressure pchamber : 6.89->6.92 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4463 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.96 over 8.39 to 16.35 [ms]
  • Mean toroidal magnetic field Bt: 0.107 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 8.7 V
  • Break down voltage: 11.2 V
  • Plasma total charge: 18.0 C
  • Ohmic heating power: 18.3 kW
  • Q edge: 4.6
  • Central electron temperature: 34.8 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and