Golem shot: 5151

2011-04-05 - 085229

Basic parameters:
  • Chamber pressure pchamber : 5.56->5.50 mPa (vacuum shot)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 905 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.32 over 10.39 to 16.71 [ms]
  • Mean toroidal magnetic field Bt: 0.096 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 1.2 V
  • Break down voltage: 0.5 V
  • Plasma total charge: 21.1 C
  • Ohmic heating power: 2.4 kW
  • Q edge: 4.3
  • Central electron temperature: 126.2 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and