Golem shot: 5157

2011-04-05 - 100429

Basic parameters:
  • Chamber pressure pchamber : 5.43->5.43 mPa (vacuum shot)
  • Chamber temperature: 3 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3384 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.5 over 2.78 to 11.28 [ms]
  • Mean toroidal magnetic field Bt: 0.074 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 6.8 V
  • Break down voltage: 9.4 V
  • Plasma total charge: 2.8 C
  • Ohmic heating power: 6.8 kW
  • Q edge: 6.7
  • Central electron temperature: 25.0 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and