Golem shot: 5159

2011-04-05 - 101042

Basic parameters:
  • Chamber pressure pchamber : 5.48->20.27 mPa (request: 20 mPa)
  • Chamber temperature: 19 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3759 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.8 over 7.79 to 16.59 [ms]
  • Mean toroidal magnetic field Bt: 0.095 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: 6.7 V
  • Break down voltage: 9.4 V
  • Plasma total charge: 14.2 C
  • Ohmic heating power: 12.1 kW
  • Q edge: 4.8
  • Central electron temperature: 37.4 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and