Golem shot: 5165

2011-04-05 - 120254

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.70->19.43 mPa (request: 20 mPa)
  • Chamber temperature: 88 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10494 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.31 over 6.73 to 15.04 [ms]
  • Mean toroidal magnetic field Bt: 0.113 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 5.9 V
  • Break down voltage: 9.2 V
  • Plasma total charge: 14.2 C
  • Ohmic heating power: 12.4 kW
  • Q edge: 4.9
  • Central electron temperature: 45.1 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and