Golem shot: 5166

2011-04-05 - 120524

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.71->20.66 mPa (request: 20 mPa)
  • Chamber temperature: 67 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10658 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.71 over 12.23 to 19.94 [ms]
  • Mean toroidal magnetic field Bt: 0.160 T
  • Mean plasma current: 3.7 kA
  • Mean Uloop: 6.7 V
  • Break down voltage: 10.8 V
  • Plasma total charge: 45.3 C
  • Ohmic heating power: 24.8 kW
  • Q edge: 3.9
  • Central electron temperature: 60.4 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and