Golem shot: 5177

2011-04-05 - 123231

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.80->20.12 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 12306 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.51 over 12.85 to 20.36 [ms]
  • Mean toroidal magnetic field Bt: 0.254 T
  • Mean plasma current: 3.5 kA
  • Mean Uloop: 7.3 V
  • Break down voltage: 10.3 V
  • Plasma total charge: 44.6 C
  • Ohmic heating power: 25.6 kW
  • Q edge: 6.6
  • Central electron temperature: 55.0 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and