Golem shot: 5179

2011-04-06 - 122414

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.09->5.09 mPa (vacuum shot)
  • Chamber temperature: 91 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 19355 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.14 over 7.93 to 16.07 [ms]
  • Mean toroidal magnetic field Bt: 0.107 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 9.0 V
  • Break down voltage: 11.5 V
  • Plasma total charge: 13.7 C
  • Ohmic heating power: 15.3 kW
  • Q edge: 5.7
  • Central electron temperature: 29.6 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and