Golem shot: 5180

2011-04-06 - 122607

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.07->5.11 mPa (vacuum shot)
  • Chamber temperature: 80 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 19470 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.2 over 1.76 to 9.96 [ms]
  • Mean toroidal magnetic field Bt: 0.078 T
  • Mean plasma current: 0.7 kA
  • Mean Uloop: 9.2 V
  • Break down voltage: 11.6 V
  • Plasma total charge: 1.3 C
  • Ohmic heating power: 6.4 kW
  • Q edge: 10.1
  • Central electron temperature: 16.1 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and