Golem shot: 5182

2011-04-06 - 122946

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.17->24.00 mPa (request: 20 mPa)
  • Chamber temperature: 67 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 19695 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.52 over 10.46 to 17.98 [ms]
  • Mean toroidal magnetic field Bt: 0.154 T
  • Mean plasma current: 2.4 kA
  • Mean Uloop: 8.6 V
  • Break down voltage: 10.0 V
  • Plasma total charge: 25.3 C
  • Ohmic heating power: 20.6 kW
  • Q edge: 5.8
  • Central electron temperature: 38.3 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and