Basic parameters:
  • Chamber pressure pchamber : 4.45->4.48 mPa (vacuum shot)
  • Chamber temperature: 53 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4950 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.13 over 4.27 to 10.4 [ms]
  • Mean toroidal magnetic field Bt: 0.056 T
  • Mean plasma current: 0.6 kA
  • Mean Uloop: 6.3 V
  • Break down voltage: 0.1 V
  • Plasma total charge: 2.8 C
  • Ohmic heating power: 3.8 kW
  • Q edge: 8.4
  • Central electron temperature: 18.7 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK