Golem shot: 5191

2011-04-07 - 124704

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 4.62->4.68 mPa (vacuum shot)
  • Chamber temperature: 45 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5097 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.12 over 12.8 to 18.92 [ms]
  • Mean toroidal magnetic field Bt: 0.102 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 1.0 V
  • Break down voltage: 0.1 V
  • Plasma total charge: 15.8 C
  • Ohmic heating power: 1.2 kW
  • Q edge: 7.7
  • Central electron temperature: 101.4 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and