Golem shot: 5197

2011-04-07 - 131027

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.27->20.19 mPa (request: 20 mPa)
  • Chamber temperature: 19 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6507 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.93 over 9.74 to 17.67 [ms]
  • Mean toroidal magnetic field Bt: 0.114 T
  • Mean plasma current: 2.9 kA
  • Mean Uloop: 7.6 V
  • Break down voltage: 11.0 V
  • Plasma total charge: 27.9 C
  • Ohmic heating power: 22.0 kW
  • Q edge: 3.5
  • Central electron temperature: 47.2 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and