Golem shot: 5198

2011-04-07 - 132732

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.33->5.33 mPa (vacuum shot)
  • Chamber temperature: 13 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7525 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.6 over 3.41 to 12.01 [ms]
  • Mean toroidal magnetic field Bt: 0.099 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: 4.7 V
  • Break down voltage: 6.8 V
  • Plasma total charge: 3.6 C
  • Ohmic heating power: 5.2 kW
  • Q edge: 8.1
  • Central electron temperature: 34.1 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and